Description Details
X-radiation 10 kV - 420 kV (DIN 6809/4, 1988; DIN 6809/5, 1996)(1)

γ-radiation, 60Co (DIN 6800/2, 2008)(2)

To top

Reference air kerma rate

Contact person: Opens window for sending emailDr. R. Behrens(at)ptb.de,
Phone: +49 531 592 6340, Fax: +49 531 592 69 6340

Description Details
γ-radiation, 192Ir

γ-radiation, 60Co
X-radiation and γ-radiation, 125I

To top

Ambient dose equivalent rate in 10 mm depth

1) Contact person: Opens window for sending emailDr. H. Zutz(at)ptb.de,
    Phone: +49 531 592 6310

Order form for Initiates file downloadcalibrations/tests; Orderform for Initiates file downloadirradiation (to fill in)

2) Contact person: Opens window for sending emailDr. F. Krasniqi(at)ptb.de,
    Phone: +49 531 592 6320

Description Details
X-radiation (ISO 4037)

Gamma radiation (ISO 4037)(1)
Gamma radiation (Calibration at low dose rates)(2)

High-energy photon radiation (ISO 4037)

To top

Directional dose equivalent rate in 0.07 mm depth

Contact person: Opens window for sending emailDr. H. Zutz(at)ptb.de,
Phone: +49 531 592 6310

Order form for Initiates file downloadcalibrations/tests; Orderform for Initiates file downloadirradiation (to fill in)

Description Details
X-radiation (ISO 4037)

Gamma radiation (ISO 4037)

To top

Personal dose equivalent in 10 mm depth

Contact person: Opens window for sending emailDr. H. Zutz(at)ptb.de,
Phone: +49 531 592 6310

Order form for Initiates file downloadcalibrations/tests; Orderform for Initiates file downloadirradiation (to fill in)

Description Details
X-radiation (ISO 4037)

Gamma radiation (ISO 4037)

High-energy photon radiation (ISO 4037)

To top

Personal dose equivalent in 0.07 mm depth

Contact person: Opens window for sending emailDr. H. Zutz(at)ptb.de,
Phone: +49 531 592 6310

Order form for Initiates file downloadcalibrations/tests; Orderform for Initiates file downloadirradiation (to fill in)

Description Details
X-radiation (ISO 4037)

Gamma radiation (ISO 4037)

To top

Air kerma rate

1) Contact person : Dr. L. Büermann, Opens local program for sending emailCaliGray(at)ptb.de
    Phone : +49 531 592 6250

2) Contact person : Opens window for sending emailDr. F. Krasniqi(at)ptb.de,
    Phone : +49 531 592 6320

3) Contact person : Opens window for sending emailDr. H. Zutz(at)ptb.de,
    Phone : +49 531 592 6310

Description Details
X-rays, diagnostic (IEC 61267)(1)
X-rays, radiation protection (ISO 4037)(1)
Gamma radiation (ISO 4037)(1)
Gamma radiation (Calibration at low dose rates)(2)

High-energy photon radiation (ISO 4037)(3)


To top

Air kerma-length product

Contact person: Dr. L. Büermann, Opens local program for sending emailCaliGray(at)ptb.de
Phone: +49 531 592 6250

Description Details
X-rays, diagnostic (IEC 61267)

To top

Air kerma-area product

Contact person: Dr. L. Büermann, Opens local program for sending emailCaliGray(at)ptb.de
Phone: +49 531 592 6250

Description Details
X-rays, diagnostic (IEC 61267)

To top

X-ray tube voltage

Contact person: Dr. L. Büermann, Opens local program for sending emailCaliGray(at)ptb.de
Phone: +49 531 592 6250

Description Details
X-rays, diagnostic (IEC 61267)

To top

Beta radiation

Directional dose equivalent rate in 0.07 mm depth

Contact person: Dr. R. Behrens(at)ptb.de,
Phone: +49 531 592 6340, Fax: +49 531 592 69 6340

Orderform for Initiates file downloadirradiation (to fill in)

Description Details
Pm, Kr, Sr/Y, Ru/Rh (ISO 6980)

To top

Personal dose equivalent in 0.07 mm depth

Contact person: Dr. R. Behrens(at)ptb.de,
Phone: +49 531 592 6340, Fax: +49 531 592 69 6340

Orderform for Initiates file downloadirradiation (to fill in)

Description Details
Pm, Kr, Sr/Y, Ru/Rh (ISO 6980)

To top

Eye lens personal dose

Contact person: Opens window for sending emailDr. R. Behrens(at)ptb.de,
Phone: +49 531 592 6340, Fax: +49 531 592 69 6340

Description Details
Sr/Y, Ru/Rh (ISO 6980)

To top

Absorbed dose rate to ICRU soft tissue

Contact person: Dr. R. Behrens(at)prb.de,
Phone: +49 531 592 6340, Fax: +49 531 592 69 6340

Orderform for irradiation (to fill in)

Description Details
C, Pm, Tl, Kr, Sr/Y, Ru/Rh (ISO 6980)

To top