Logo of the Physikalisch-Technische Bundesanstalt

Investigations into damping in building acoustics by use of downscaled models

03.09.2008

In the frame of a doctoral thesis [1] basic investigations into damping effects in the field of building acoustics have been carried out. Special interest is paid to the damping of a partition wall in a laboratory test facility. This damping directly affects sound insulation which is the most important quantity in building acoustics.

In accordance with the results of earlier examinations, investigations into damping effects in the field of building acoustics were applied to small downscaled models. These offer the advantage of the exact execution of construction and of freely selectable material properties and allow idealised constructions to be realised. Firstly, the necessary theoretical and experimental bases were provided for the design of the downscaled models. Extensive investigations into material properties led to the parameters required for the experiments and simulations. Thereafter, the individual effects that lead to the damping of the partition wall were determined as loss factors by experiment. A simulation undertaken by means of statistical energy analysis (SEA) allowed detailed insight into the energies and power flows of the system in total to be gained. Both the experiment and the simulation showed in agreement that the power flowing from the facility into the partition cannot be neglected a priori as has been common up to now. Depending on the laboratory situation, effects which have been thought of as loss effects to date can be turned into gain effects for the partition.
Since the power flows are the basis for the treatment of loss factors which are the measurement quantities for the damping of a partition wall, the complexity of power flows requires a rethink. Previous conclusions and measurement procedures must be tested for validity. Particularly, the standard procedure for measuring the total loss factor, which is the main measurement quantity for damping in practise, was analysed by a transient SEA simulation. In agreement with model measurements, it could be shown that, due to the complex power flow in a wall test facility, the total loss factor is determined as much too low for typical standard situations.
The insights gained about the damping of a partition wall in a building acoustics test facility explain previous discrepancies but also raise some new questions of a basic nature. In future, more effort will be required in practise to determine the influence of damping. This thesis offers a starting point for that.

Power flow of a partition wall with stationary excitation in the sending room. According to the classical view (a), the irradiation of sound from the sending room is the only mechanism which leads to a power input into the partition. Coupling to other neighbouring systems means only power loss to the partition wall. It could be shown that the actual power flow is more complex and depends on frequency and the properties of the building elements and the junctions. This can lead to a totally different behaviour of the wall (b).

Figure 1: Power flow of a partition wall with stationary excitation in the sending room. According to the classical view (a), the irradiation of sound from the sending room is the only mechanism which leads to a power input into the partition. Coupling to other neighbouring systems means only power loss to the partition wall. It could be shown that the actual power flow is more complex and depends on frequency and the properties of the building elements and the junctions. This can lead to a totally different behaviour of the wall (b).

[1] Christoph Kling: Investigations into Damping in Building Acoustics by Use of Downscaled Models. Dissertation, Aachen 2008. Aachener Beiträge zur Technischen Akustik, Band 7. Logos-Verlag Berlin, ISBN 978-3-8325-1985-8. (online available via the web site of the Central Library of the RWTH Aachen University)

Contact person:

Christoph Kling, FB 1.6, AG 1.62, Christoph.Kling@ptb.de