Logo der Physikalisch-Technischen Bundesanstalt

Aktuelle Forschungsnachrichten und Nachrichten aus dem Jahresbericht

Comparing form measurement data for aspheres and freeform surfaces is an important tool for ensuring the quality and functionality of the devices used to take such measurements and may also allow the underlying measurement methods to be evaluated. However, comparing the highly accurate form measurements of such complex surfaces is a demanding task. It is difficult to analyze measurement results whose accuracies are in the range of several tens of nanometers root-mean-square, especially when comparing data with different, and anisotropic distributions of the 3D measurement points on the surface under test. In this paper, we investigate eight different 3D measurement point distributions that are typical of highly accurate measurement systems currently in use and demonstrate the effects of these distributions on the comparison results by using virtually generated data and applying different evaluation strategies. The results show that, for the examples investigated, the different 3D measurement point distributions can yield different levels of accuracy for the comparison. Furthermore, an improved evaluation procedure is proposed and recommendations on how to significantly reduce the influence of the different 3D measurement point distributions on the comparison result are given. A method of employing virtually generated test data is presented that may be generalized in order to further improve and validate future comparison methods.

[ mehr ]

An LED sphere radiator (LED-SR) was constructed to improve the accuracy in spectral radiance factor measurements performed with the robot-based gonioreflectometer at PTB. Its properties with respect to the spectral range and coverage, the temporal stability, and the homogeneity of the radiation field are presented. Two types of matte ceramic reflection standards were used for spectral radiance factor validation measurements comparing the standardly used halogen sphere radiator (Halogen-SR) and the LED-SR. Due to its designed spectral range at the border between the visible and the UV-A spectral range, the LED-SR is well suited for many applications in diffuse reflectometry. Its use for absolute radiance factor measurements and investigations of the fluorescence properties of diffuse reflecting samples is shown. Reliable polarization-resolved measurements at wavelengths below 430 nm could be carried out with PTB’s gonioreflectometer for the first time due to the beneficial signal-to-noise ratio of the LED-SR.

[ mehr ]