Darstellung Drehmoment

Arbeitsgruppe 1.22

Nach oben

Normalmesseinrichtungen, Kalibriereinrichtungen

Geva, Kai; Kahmann, Holger; Schlegel, Christian; Kumme, Rolf
Analysis of the measurement uncertainty of a new measurement flexure calibration set-up
Acta IMEKO Special issue for TC3, TC5, TC16 and TC22 (2020)
DOI: Opens external link in new windowhttp://dx.doi.org/10.21014/acta_imeko.v9i5.963

Baumgarten, Sebastian; Röske, Dirk; Hiiro, Jussi Ala; Vavrecka, Lukáš ; Kock, Stefan; Gnauert, Jonas
Parasitic loads in torque standard machines: a characterization, comparison, and evaluation
Acta IMEKO 8 (2019) 3, 78-89
DOI: Opens external link in new windowdoi.org/10.21014/acta_imeko.v8i3.607

Brüge, Andreas; Pfeiffer, Harald
A standard for rotatory power measurement
Acta IMEKO 8 (2019) 3, 48-58
DOI: Opens external link in new windowdoi.org/10.21014/acta_imeko.v8i3.561

Schlegel, Christian; Röske, Dirk; Mauersberger, Dietmar; Hohmann, Paul
Metrological characterization of a 20 N·m torque calibration standard machine at PTB, Germany
XXII IMEKO World Congress: Knowledge through Measurement, Belfast, 03-06 September, 2018
DOI: Opens external link in new windowhttps://doi.org/10.1088/1742-6596/1065/4/042026

Härtig, Frank; Hornig, Julia; Kahmann, Holger; Kniel, Karin; Müller, Harald; Schlegel, Christian
Metrological Competence Center for Windenergy
XXII IMEKO World Congress: Knowledge through Measurement, Belfast, 03-06 September, 2018
DOI: Opens external link in new windowhttps://doi.org/10.1088/1742-6596/1065/4/042053

Foyer, Gisa; Kahmann, Holger
Design of a force lever system to allow traceable calibration of MN·m torque in nacelle test benches
Sensoren und Messsysteme; Beiträge zur 19. ITG/GMA-Fachtagung (ITG-Fachbericht: 281) (2018)

Kahmann, Holger; Schlegel, Christian; Kumme, Rolf; Röske, Dirk
Principle and design of a 5 MN·m torque standard machine
IMEKO TC3, TC5 and TC22 International Conference 2017, Helsinki, 30 May - 01 June, 2017
Link: Opens external link in new windowhttps://www.imeko.org/publications/tc3-2017/IMEKO-TC3-2017-037.pdf

Schlegel, Christian; Kahmann, Holger; Weidinger, Paula; Kumme, Rolf
New perspectives for MN·m torque measurement at PTB
IMEKO TC3, TC5 and TC22 International Conference 2017, Helsinki, 30 May - 01 June, 2017
Link: Opens external link in new windowhttps://www.imeko.org/publications/tc3-2017/IMEKO-TC3-2017-045.pdf

Härtig, Frank; Kniel, Karin; Schlegel, Christian; Müller, Harald
Kompetenzzentrum für Windenergie
Ingenieurspiegel (2016)

Baumgarten, Sebastian; Kahmann, Holger; Röske, Dirk
Metrological characterization of a 2 kN·m torque standard machine for superposition with axial forces up to 1 MN
Metrologia 53(5):1165-1176, 2016
DOI: doi.org/10.1088/0026-1394/53/5/1165

Schlegel, Christian; Kahmann, Holger; Kumme, Rolf
MN·m torque calibration for nacelle test benches using transfer standards
Acta IMEKO 5 (2016) 4, 12-18
DOI: Opens external link in new windowdoi.org/10.21014/acta_imeko.v5i4.414

Schlegel, Christian; Kahmann, Holger; Kumme, Rolf
Torque calibration for nacelle test benches in the MN· m range
14th IMEKO TC10 Technical Diagnostics Workshop on New Perspectives in Measurements, Tools and Techniques for system’s reliability, maintainability and safety, Milano, 27-28, June, 2016
Link: Opens external link in new windowhttps://www.imeko.org/publications/tc10-2016/IMEKO-TC10-2016-039.pdf

Woźniak, M.; Röske, D.
Investigation of the calibration and measurement capabilities of the new 5 kN·m torque calibration machine at GUM
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 443-446
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-092.pdf

Fraiss, Hans Jörg; Stenner, Lioba; Röske, D.
Development of a New 400 kN·m Torque Calibration Machine
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 196-200
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-039.pdf

Sanponpute, Tassanai; Arksonnarong, Nittaya; Brüge, Andreas; Saenkhum, Nattapon
Suspended-fulcrum torque standard machine, 2nd report
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 373-376
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-078.pdf

Röske, D.
Metrological characterization of a 1 N m torque standard machine at PTB, Germany
Metrologia 51 (2014) 87-96
Link: http://iopscience.iop.org/0026-1394/51/1/87/

Baumgarten, S.; Röske, D.; Kahman, H.; Mauersberger, D.; Kumme, R.
Force/Torque measuring facility for friction coefficient and multi-component sensors
AMA Conferences, Sensor, Opto, IRS2, 14. -16.5. 2013, Nürnberg, S. 28-33

Baumgarten, S.; Röske, D.; Kahmann, H.; Mauersberger, D.; Kumme, R.
Design of a facility for the precise simultaneous generation and measurement of force and torque
XX IMEKO World Congress, Metrology for Green Growth, 9. – 14. Sept. 2012, Busan Republic of Korea
Link: http://www.imeko.org/publications/wc-2012/IMEKO-WC-2012-TC3-O17.pdf

Röske, D.
Messunsicherheiten bei der Drehmomentmessung mit Referenzmesseinrichtungen
Technisches Messen, Vol. 78, 2011, No 2,  S. 77-87

Brüge, A.; Röske, D.; Mauersberger, D.; Adolf, K.
Influence of cross forces and bending moments on reference torque sensors for torque wrench calibration
Proc. of the XIX IMEKO World Congress "Fundamental and Applied Metrology”, Lisbon, Portugal, 6-11 September 2009, p. 356-361
Link: http://www.imeko.org/publications/wc-2009/IMEKO-WC-2009-TC3-330.pdf

Röske, D.
Uncertainty considerations for the physical quantity torque
China industry system - Technical Seminar of Torque Metrology Technology, Shanghai, 30, November - 04, December, 2006, China, 193 - 201

Röske, D.; Mauersberger, D.
On the stability of measuring devices for torque key comparisons
IMEKO XVIII World Congress and IV Brazilian Congress of Metrology, "Metrology for a Sustainable Development", Rio de Janeiro, 17-22, September, 2006, Brazil, on CD-ROM, file name: 00181.pdf

Peschel, D.; Röske, D.
Messunsicherheiten bei der Drehmomentmessung
Technisches Messen: 72 (2005), 5, 308 - 324

Röske, D.
Key comparisons in the field of torque measurement
19th International Conference on Force, Mass and Torque (IMEKO TC3): "Theory and Application in Laboratories and Industries", Cairo, 19-23, February, 2005, Egypt, on CD-ROM, file name: pdf\36.pdf

Bruns, Th.
Sinusoidal Torque Calibration: A Design for Traceability in Dynamic Torque Calibration
Proceedings of the XVII IMEKO World Congress (CD-ROM, file: TC3.pdf), "Metrology in the 3rd Millennium", Dubrovnik, Croatia, June 22-27, 2003

Ohgushi, K.; Ota, T.; Ueda, K.; Peschel, D.; Bruns, Th.
Load Dependency of the Moment-Arm Length in the Torque Standard Machine
Proceedings of the XVII IMEKO World Congress (CD-ROM, file: TC3.pdf), "Metrology in the 3rd Millennium", Dubrovnik, Croatia, June 22-27, 2003

Peschel, D.; Bruns, Th.; Weilu, S.; Yan, W.
Intercomparisons in Torque - What are Important criteria?
Proceedings of the Joint International Conference IMEKO TC3/TC5/TC20, Celle, Germany, 2002, VDI-Berichte 1685, VDI-Verlag GmbH, Düsseldorf, 2002, pp. 317-326

Röske, D.; Adolf K.; Peschel, D.
Lever Optimization for Torque Standard Machines
Proceedings of the XVIth IMEKO World Congress, September 25-28, 2000, Vienna, Austria, vol. III, pp. 247-251

Röske, D.
Zum Einfluss mechanischer Störkomponenten auf die Messung von Drehmomenten mit DMS-Aufnehmern
PTB-Bericht MA-63, Braunschweig, 1999

Peschel, D.
The State of the Art and Future Development of Metrology in the Field of Torque Measurement in Germany
Proceedings of the XIVth IMEKO World Congress, June 1-6, 1997, Tampere, Finland, vol. III, pp. 65-71

Brüge, A.
Influence of Rotation on Rotary Torque Transducers Calibrated without Rotation
Proceedings of the XIVth IMEKO World Congress, June 1-6, 1997, Tampere, Finland, vol. III, pp. 79-84

Peschel, D.
Proposal for the Design of Torque Calibration Machines Using the Principle of a Component System
Proceedings of the 15th IMEKO TC3 Conference, October 7-11, 1996, Madrid, Spain, pp. 251-254

Brüge, A.
Influence of Eccentric Mounting on the Calibration of Torque Measuring Devices
Proceedings of the 15th IMEKO TC3 Conference, October 7-11, 1996, Madrid, Spain, pp. 255-259

Röske, D.
Realization of the Unit of Torque - Determination of the Force-Acting Line Position in Thin Metal Belts
Proceedings of the 15th IMEKO TC3 Conference, October 7-11, 1996, Madrid, Spain, pp. 261-264

Ahedo, D. R.; Guzman, J. C. T.; Peschel, D.:
Diese´no y construcción de un sistema de medición de par torsional en CENAM (Mexico)
Metrology 96, International Conference Center of Havanna, October 29 - 31, 1996, Havanna, Cuba

Adolf, K.; Mauersberger, D.; Peschel, D.
Specifications and Uncertainty of Measurement of the PTB's 1 kNm Torque Standard Machine
Proceedings of the 14th IMEKO TC3 Conference, September 5-8, 1995, Warsaw, Poland, pp. 174-176

Röske, D.; Adolf, K.
On the Problem of Lever Arm Lengths in the Realization of the Torque - Finite Element Calculations on Lever Models
Proceedings of the 14th IMEKO TC3 Conference, September 5-8, 1995, Warsaw, Poland, pp. 178-182

Röske, D.
Finite Element Calculations on an Elastic Body for a Torque Transducer with Integrated Cross Force Measurement
Proceedings of the 14th IMEKO TC3 Conference, September 5-8, 1995, Warsaw, Poland, pp. 183-184

Peschel, D.; Mauersberger, D.
Determination of the Friction of Aerostatic Radial Bearings for the Lever-Mass System of Torque Standard Machines
Proceedings of the XIIIth IMEKO World Congress, September 5-9, 1994, Torino, Italy, pp. 216-220

Nach oben

Drehmomentaufnehmer, Mehrkomponentensensoren und -messeinrichtungen

Brüge, Andreas
On the regression of sensitivity characteristics of torque transducers
Acta IMEKO Special issue for TC3, TC5, TC16 and TC22 (2020)
DOI: Opens external link in new windowhttp://dx.doi.org/10.21014/acta_imeko.v9i5.968

Foyer, Gisa; Kock, Stefan; Weidinger, Paula
Influences on torque measurement in nacelle test benches and their effect on the measurement uncertainty and consequences of a torque calibration
Acta IMEKO 8 (2019) 3, 59-68
DOI: Opens external link in new windowdoi.org/10.21014/acta_imeko.v8i3.658

Weidinger, Paula; Foyer, Gisa; Kock, Stefan; Gnauert, Jonas; Kumme, Rolf
Torque calibration in the MN m range under rotation in a nacelle test bench
20. GMA-ITG Fachtagung Sensoren und Messsysteme 2019, Nürnberg, 25-26, Juni, 2019
DOI: https://doi.org/10.5162/sensoren2019/5.1.3

Weidinger, Paula; Foyer, Gisa; Kock, Stefan; Gnauert, Jonas; Kumme, Rolf
Calibration of torque measurement under constant rotation in a wind turbine test bench
J. Sens. Sens. Syst., 8, 149–159, 2019
DOI: https://doi.org/10.5194/jsss-8-149-2019

Weidinger, Paula; Foyer, Gisa
Traceable torque measurement under rotation in nacelle test benches: a good practice guide, 2019
DOI: Opens external link in new windowhttps://doi,org/10.7795/530.20190111

Weidinger, Paula; Foyer, Gisa; Ala-Hiiro, Jussi; Schlegel, Christian; Kumme, Rolf
Investigations towards extrapolation approaches for torque transducer characteristics
XXII IMEKO World Congress: Knowledge through Measurement, Belfast, 03-06 September, 2018
DOI: Opens external link in new windowhttps://doi.org/10.1088/1742-6596/1065/4/042057

Brüge, Andreas
Separating eccentricity deviation in transfer torque wrench calibrations
XXII IMEKO World Congress: Knowledge through Measurement, Belfast, 03-06 September, 2018
DOI: doi.org/10.1088/1742-6596/1065/4/042023

Weidinger, Paula; Foyer, Gisa; Kock, Stefan; Gnauert, Jonas; Kumme, Rolf
Procedure for torque calibration under constant rotation investigated on a nacelle test bench
19. ITG-GMA-Fachtagung Sensoren und Messsysteme 2018, Nürnberg, 26-27 Juni, 2018

Weidinger, Paula; Foyer, Gisa; Kock, Stefan; Gnauert, Jonas; Kumme, Rolf
Development of a torque calibration procedure under rotation for nacelle test benches
The Science of Making Torque from Wind (Torque 2018), Milano, 20-22 June 2018
DOI: doi.org/10.1088/1742-6596/1037/5/052030

Khaled, K. M.; Röske, Dirk
The influence of temperature and humidity on the creep of torque transducers
IMEKO TC3, TC5 and TC22 International Conference 2017, Helsinki, 30 May - 01 June, 2017
Link: Opens external link in new windowhttps://www.imeko.org/publications/tc3-2017/IMEKO-TC3-2017-022.pdf

Foyer, Gisa; Kock, Stefan
Measurement uncertainty evaluation of torque measurements in nacelle test benches
IMEKO TC3, TC5 and TC22 International Conference 2017, Helsinki, 30 May - 01 June, 2017
Link: Opens external link in new windowhttps://www.imeko.org/publications/tc3-2017/IMEKO-TC3-2017-010.pdf

Weidinger, Paula; Schlegel, Christian; Foyer, Gisa; Kumme, Rolf
Characterisation of a 5 MN·m torque transducer by combining traditional calibration and finite element method simulations
Sensor 2017, 18th International Conference on Sensors and Measurement Technology, Nuremberg, 30 May - 01 June, 2017
DOI: Opens external link in new windowhttps://doi.org/10.5162/sensor2017/D6.2

Kock, Stefan; Jacobs, Georg; Bosse, Dennis; Weidinger, Paula
Torque measurement uncertainty in multi-MW nacelle test benches
3rd Conference for Wind Power Drives 2017, Aachen, 07-08 March, 2017
ISBN: 3-7431-3456-X, 978-3-7431-3456-0

Khaled, K. M.; Röske, Dirk; Abuelezz, A. E.; El-Sherbiny, M. G
The influence of temperature and humidity on the sensitivity of torque transducers
Measurement (2016)
DOI: Opens external link in new windowhttps://doi.org/10.1016/j.measurement.2016.07.028

Brüge, A.
Uncertainty restrictions of transfer click-torque wrenches
ACTA IMEKO, 4 (2015), 2, 23‐31
Link: Opens external link in new windowhttp://acta.imeko.org/index.php/acta-imeko/article/download/IMEKO-ACTA-04%20%282015%29-02-05/394

Brüge, A.
Refined uncertainty budget for reference torque calibration facilities
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 159-165
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-033.pdf

Baumgarten; S.; Röske, D. and Kumme, R.
Completion and measurement unvcertainty budget of the multi-component measuring device for force up to 1 MN and torque up to 2 kN·m
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 150-154
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-031.pdf

Ogushi, K.; Baumgarten, S.; Röske, D.
Another approach analyzing the crosstalk matrix for a precise force-torque transducer
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 329-332
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-068.pdf

Brüge, A.
Operating conditions for transfer click-torque wrenches
IMEKO International TC3, TC5 and TC22 Conference 2014, Cape Town, South Africa, 3 – 5 February 2014
Link: Opens external link in new windowhttp://www.imeko.org/publications/tc3-2014/IMEKO-TC3-2014-017.pdf

Brüge, A.
Creep Measurements in Reference Torque Calibration Machines
IMEKO 2010 TC3, TC5 and TC22 Conferences Metrology in Modern Context, Pattaya, Chonburi, Thailand, November 22-25, 2010, CD-ROM, p. 95-98
Link: http://www.imeko.org/publications/tc3-2010/IMEKO-TC3-2010-NP-023.pdf

Park, Y.-K.; Kumme, R.; Roeske, D.; Kang, D.-I.
Evaluation of multi-component force transducers having column type sensing element
Proc. of the XIX IMEKO World Congress "Fundamental and Applied Metrology”, Lisbon, Portugal, 6-11 September 2009, p. 368-372
Link: http://www.imeko.org/publications/wc-2009/IMEKO-WC-2009-TC3-157.pdf

Lietz, S.; Tegtmeier, F. L.; Kumme, R.; Röske, D.; Kolwinski, U.; Zöller, K.
A new six-component force vector sensor - first investigations
IMEKO TC3 & TC16 & TC22 International Conference : 27th November - 1st December, 2007, Merida, Mexico, on CD-ROM, file name: ID-006.pdf

Röske, D.
Metrological Characterization of a Hexapod for a Multi-component Calibration Device
Proceedings of the XVII IMEKO World Congress (CD-ROM, file: TC3.pdf), "Metrology in the 3rd Millennium", Dubrovnik, Croatia, June 22-27, 2003

Röske, D.
Investigation of Different Joint Types for a Multi-component Calibration Device Based on a Hexapod Structure
Proceedings of the Joint International Conference IMEKO TC3/TC5/TC20, Celle, Germany, 2002, VDI-Berichte 1685, VDI-Verlag GmbH, Düsseldorf, 2002, pp. 27-34

Röske, D.; Peschel, D.; Adolf, K.
The Generation and Measurement of Arbitrarily Directed Forces and Moments: the Project of a Multicomponent Calibration Device Based on a Hexapod Structure
Proceedings of the 17th International Conference of IMEKO TC3 "Force, Mass, Torque and Pressure Measurements at Present and in the Future", Istanbul, Turkey, 17-21, September, 2001, pp. 339-349

Merlo, S.; Röske, D.
A Six-Component Standard: A Feasibility Study
Proceedings of the XVIth IMEKO World Congress, September 25-28, 2000, Vienna, Austria, vol. III, pp. 193-198

Röske, D.
A Multicomponent Force and Moment Transducer for Use in a 20 kN·m Torque Standard Machine
Proceedings of the XXI Convegno Dell'Associazione Italiana Per L'Analisi Delle Sollecitazioni, September 23-26, 1992,

Nach oben

Spezielle Effekte, Theoretische Betrachtungen

Foyer, Gisa; Kahmann, Holger
A finite element analysis of effects on force lever systems under nacelle test bench conditions
XXII IMEKO World Congress: Knowledge through Measurement, Belfast, 03-06, September, 2018
DOI: Opens external link in new windowhttps://doi.org/10.1088/1742-6596/1065/4/042006

Brüge, Andreas
Traceability of bridge amplifiers in tared measurement applications
IMEKO TC3, TC5 and TC22 International Conference 2017, Helsinki, 30, May - 01, June, 2017
Link: Opens external link in new windowhttps://www.imeko.org/publications/tc3-2017/IMEKO-TC3-2017-027.pdf

Weidinger, Paula; Schlegel, Christian; Foyer, Gisa; Kumme, Rolf
Extending the torque calibration range - necessity and outline of a mathematical approach
VII International Competition of COOMET "BEST YOUNG METROLOGIST", Astana, 17-18, May, 2017
DOI: Opens external link in new windowdoi.org/10.24027/2306-7039.1A.2017.99993

Khaled, K. M.; Röske, D.; Abuelezz, A. E.; Elsherbiny, M.G.
Humidity and temperature effects on torque transducers, bridge calibration unit and amplifiers
Measurement 74 (2015) 31–42
Link: Opens external link in new windowhttp://dx.doi.org/10.1016/j.measurement.2015.07.007

Röske, D.
Uncertainty calculations using free CAS software MAXIMA
IMEKO International TC3, TC5 and TC22 Conference 2014, Cape Town, South Africa, 3 – 5 February 2014
Link: Opens external link in new windowhttp://www.imeko.org/publications/tc3-2014/IMEKO-TC3-2014-016.pdf

Brüge, A.
Simplified Measurements of the relative Humidity Coefficient of Torque Transducers in Calibration Laboratories
Acta IMEKO, June 2014, Vol 3, No 2 (2014), pp. 32 – 38
Link: Opens external link in new windowhttp://acta.imeko.org/index.php/acta-imeko/article/viewFile/IMEKO-ACTA-03 (2014)-02-09/257

Brüge, A.
Influence of Humidity to Torque Transducers – Estimation Methods for Calibration Laboratories
XX IMEKO World Congress, Metrology for Green Growth, 9. – 14. Sept. 2012, Busan, Republic of Korea
Link: http://www.imeko.org/publications/wc-2012/IMEKO-WC-2012-TC3-O30.pdf

Röske, D.
Uncertainty Contribution in the Case of Cosine Function with Zero Estimate – a Proposal
IMEKO 2010 TC3, TC5 and TC22 Conferences Metrology in Modern Context,
Pattaya, Chonburi, Thailand, November 22-25, 2010
Link: http://www.imeko.org/publications/tc3-2010/IMEKO-TC3-2010-028.pdf

Brüge. A.
Mathematical representation of reference torque transducers in partial-range regimes
20th International Conference IMEKO TC3 & TC16 & TC22: 27th November - 1st December, 2007, Merida, Mexico
Link: http://www.imeko.org/publications/tc3-2007/IMEKO-TC3-2007-098u.pdf

Brüge, A.; Peschel, D.; Röske, D.
The Influence of Misalignment on Torque Transducers
Proceedings of the XVIth IMEKO World Congress, September 25-28, 2000, Vienna, Austria, vol. III, pp. 13-17

Peschel, D.; Röske, D.
Particular aspects in the calibration and application of strain gauge torque measuring devices for quasi-static alternating torque loading
Measurement, Vol. 27, No. 1, January 2000, pp. 53–60
DOI: http://dx.doi.org/10.1016/S0263-2241(99)00056-1

Peschel, D.; Röske, D.
Determination of Creep Value Using Short-Term Creep
Proceedings of the XVth IMEKO World Congress, June 13-18, 1999, Osaka, Japan, vol. III, pp. 245-249

Röske, D.
Investigation of the Influence of Disturbing Components on the Torque Measurement
Proceedings of the 16th IMEKO TC3 Conference, September 14-18, 1998, Taejon, Korea, pp. 280-285

Röske, D.
The Influence of Disturbing Components on the Torque Measurement, Demonstrated by the Example of Transducer Asymmetries
Proceedings of the XIIIth IMEKO World Congress, September 5-9, 1994, Torino, Italy, pp. 178-182

Peschel, D.
Mechanical Parasitic Components and Their Influence on the Calibration of Torque Transducers

Proceedings of the 13th IMEKO TC3 Conference, May 10-14, 1993, Helsinki, Finland, pp. 91-96

Nach oben

Standardisierung, Normung, Kalibrierung

Röske, D.
A German calibration guideline for torque wrench calibration devices revised
XXI IMEKO World Congress, 30. August - 4. September 2015, Prague, Czech Republic, 364-368
Link: Opens external link in new windowhttp://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-076.pdf

Röske, D.
ISO 6789 under Revision – Proposals for Calibration Results of Hand Torque Tools including Measurement Uncertainty
Acta IMEKO, June 2014, Vol 3, No 2 (2014), pp. 23 – 27
Link: Opens external link in new windowhttp://acta.imeko.org/index.php/acta-imeko/article/viewFile/IMEKO-ACTA-03 (2014)-02-07/255

Röske, D.
ISO 6789:2003 Calibration results of hand torque tools with measurement uncertainty – some proposals
XX IMEKO World Congress, Metrology for Green Growth, 9. – 14. Sept. 2012, Busan, Republic of Korea
Link: http://www.imeko.org/publications/wc-2012/IMEKO-WC-2012-TC3-O34.pdf

Röske, D.
The new version of the German torque calibration standard DIN 51309:2005-12 : a comparative overview
IMEKO TC3 & TC16 & TC22 International Conference: 27th November - 1st December, 2007, Merida, Mexico, on CD-ROM, file name: ID-101.pdf
Link: http://www.imeko.org/publications/tc3-2007/IMEKO-TC3-2007-KL-101u.pdf

Brüge, A.
Fast Torque Calibrations Using Continuous Procedures
Proceedings of the Joint International Conference IMEKO TC3/TC5/TC20, Celle, Germany, 2002, VDI-Berichte 1685, VDI-Verlag GmbH, Düsseldorf, 2002, pp. 343-348

Peschel, D.; Brüge, A.
Calibration of Torque Measuring Devices - Step-by-step or Continuous Procedure
Proceedings of the 16th IMEKO TC3 Conference, September 14-18, 1998, Taejon, Korea, pp. 275-279

Röske, D.; Peschel, D.
Investigations into the Alternating Torque Calibration of Torque Transducers
Proceedings of the XIVth IMEKO World Congress, June 1-6, 1997, Tampere, Finland, vol. III, pp. 72-78

Peschel, D., Röske, D.
Correlation Between Calibration Results of Torque Transducers for Right-hand/Left-hand Torque and Those for Static Alternating Torque

Poster at the 15th IMEKO TC3 Conference, October 7-11, 1996, Madrid, Spain

Nach oben

Vergleichsmessungen und Berichte

Cherepanov, Boris A.; Röske, Dirk
Final report on the torque supplementary comparison COOMET.M.T-S1 measurand torque: 0 N· m, 100 N· m, 500 kN· m, 1500 N· m, 2500 N· m
Metrologia 54(1A):07009-07009 (2017)
DOI: doi.org/10.1088/0026-1394/54/1A/07009

Röske, Dirk
Final report on the torque comparison EURAMET.M.T-S2, measurand torque: 10 N· m, 20 N· m, 40 N· m, 60 N· m, 80 N· m, and 100 N· m
Metrologia 54(1A):07005-07005 (2017)
DOI: doi.org/10.1088/0026-1394/54/1A/07005

Röske, Dirk; Ogushi, Koji
Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kN· m, 10 kN· m, 20 kN· m
Metrologia 53 07008 (2016)
DOI: Opens external link in new windowdoi.org/10.1088/0026-1394/53/1A/07008

Atsuhiro, Nishino; Koji, Ogushi; Kazunaga Ueda; Röske, D.; Mauersberger. D.
Bilateral Comparisons of Measurement Capabilities for the Calibration of Low Nominal Capacity Torque Measuring Devices between NMIJ and PTB in the Range from 0.1 N·m to 10 N·m using different procedures
Measurement 68 (2015), 32-4
Link: Opens external link in new windowhttp://dx.doi.org/10.1016/j.measurement.2015.02.030

Röske, D.
Final report on the torque key komparison CCM.T-K1.2 measurand torque: 0 N · m, 500 N · m, 1000 N · m
Metrologia 52 (2015) 07006
DOI: Opens external link in new windowhttps://doi.org/10.1088/0026-1394/52/1A/07006

Röske, D.
A German torque comparison from 20 N · m to 200 N · m and its results
IMEKO International TC3, TC5 and TC22 Conference 2014, Cape Town, South Africa, 3 – 5 February 2014
Link: Opens external link in new windowhttp://www.imeko.org/publications/tc3-2014/IMEKO-TC3-2014-015.pdf

Röske, D.
Bericht über den DKD Ringvergleich nach DIN 51309:2005-12: statische Drehmomente von 20 N · m bis 200 N · m
Expertenbericht DKD-V10.1, Ausgabe05/2014
Link: Opens external link in new windowhttp://www.ptb.de/cms/de/dienstleistungen/dkd/dkd-intern/publikationen.html
 
Koji, Ogushi; Atushiro Nishino; Koji Maeda; Kazunaga Ueda; Brüge, A.; Röske, D.
Inter-laboratory comparison of reference torque wrench calibration between NMIJ and PTB at the range from 200 N · m to 2 kN · m
AIST Bulletin of Metrology, Vol. 9, No.1, 1. March 2014, 8 pages

Koji Ogushi; Atsuhiro Nishino; Koji Maeda; Kazunaga Ueda; Andreas Brüge and Dirk Röske
Inter-laboratory Comparison of Reference Torque Wrench Calibration between NMIJ and PTB in the Range of from 200 N · m to 2 kN · m
XX IMEKO World Congress, Metrology for Green Growth, 9. – 14. Sept. 2012, Busan, Republic of Korea
Link: http://www.imeko.org/publications/wc-2012/IMEKO-WC-2012-TC3-O32.pdf

Röske, D.; Medina, N.
Final report on bilateral comparison EURAMET.M.T-S3: Torque wrenches
(10 N·m – 1 kN·m)

Metrologia 48 (2011), S. 1-19,  1A, Techn. Suppl. 07009
Link: http://www.bipm.org/utils/common/pdf/final_reports/M/T-S3/EURAMET.M.T-S3.pdf

Röske, D.
Final Report on the Torque Comparison EURAMET.M.T-S1 Measurand Torque: 1 N·m, 5 N·m, 10 N·m, 50 N·m, 200 N·m, 500 N·m, and 1000 N·m
Metrologia, 47 (2010), Tech. Suppl., 07010
Link: http://www.bipm.org/utils/common/pdf/final_reports/M/T-S1/EURAMET.M.T-S1.pdf

Röske, D.
Final report on the torque key comparison CCM.T-K1.1: Measurand torque: 0 N·m, 500 N·m, 1000 N·m
Metrologia, 47 (2010), Tech. Suppl., 07006
Link: http://dx.doi.org/10.1088/0026-1394/47/1A/07006

Röske, D.
Final report on the torque key comparison CCM.T-K1. Measurand torque: 0 N·m, 500 N·m, 1000 N·m
Metrologia: 46 (2009), Tech. Suppl., 07002 [Online only], 32 S.
Link: http://dx.doi.org/10.1088/0026-1394/46/1A/07002

Röske, D.
Die Messung des Drehmoments: von der Schraube bis zur Turbinenwelle
PTB-Mitteilungen 118 (2008) Heft 3, S. 158-165

Röske, D.
Mehrkomponentenmessungen der mechanischen Größen Kraft und Moment
PTB-Mitteilungen 118 (2008) Heft 3, S. 166-169

Pusa, A.; Röske, D.; Sachs, M.
Comparison measurements of MIKES-RAUTE 20 kN·m torque reference device with the PTB
19th International Conference on Force, Mass and Torque (IMEKO TC3): "Theory and Application in Laboratories and Industries", Cairo, 19-23, February, 2005, Egypt, on CD-ROM, file name: pdf\33.pdf

Peschel, D.; Peters, M.
WECC Inter-laboratory Comparison T1A and T1B. Torque Transducer Calibration
PTB-Bericht, PTB-MA-37, 1994

Nach oben

Normen und Richtlinien

  • Drehmomentmessgeräte für statische Drehmomente
    DIN 51309 - Kalibrierung von Drehmomentmessgeräten für statische Drehmomente, Ausgabe 2022-08, Beuth-Verlag, Berlin
    - Englische Ausgabe DIN 51309 - Materials testing machines - Calibration of static torque measuring devices

  • Drehmomentmessgeräte für statische Wechseldrehmomente
    Richtlinie DKD-R 10-5 - Statische Kalibrierung von Drehmomentmessgeräten mit Wechseldrehmoment, Ausgabe 01/2020, Revision 1,
    Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin.
    DOI: 10.7795/550.20200713, Opens external link in new windowDownload
    - Englische Ausgabe Guideline DKD-R 10-5, Static calibration of torque measuring devices with alternating torque, Edition 01/2020, Revision 1,
    Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin.
    DOI: 10.7795/550.20210407, Opens external link in new windowDownload
    - Spanische Ausgabe Directriz DKD-R 10-5, Calibración estática de instrumentos de medida de par de torsión con par alternante, Edición 01/2020, Revisión 1,
    Physikalisch-Technische Bundesanstalt, Braunschweig y Berlin.
    DOI: 10.7795/550.20210408, Opens external link in new windowDownload

  • Anzeigende Drehmomentschlüssel
    Richtlinie DKD-R 3-7, Statische Kalibrierung von anzeigenden Drehmomentschlüsseln, Ausgabe 09/2018, Revision 0,
    Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin.
    DOI: 10.7795/550.20180823H, Opens external link in new windowDownload

  • Drehmomentschraubwerkzeug-Kalibriereinrichtungen
    Richtlinie DKD-R 10-8 - Statische Kalibrierung von Kalibriereinrichtungen für Drehmomentschlüssel, Ausgabe 02/2020, Revision 0,
    Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin.
    DOI: 10.7795/550.20200210, Opens external link in new windowDownload
    - Englische Ausgabe Guideline DKD-R 10-8, Static calibration of calibration devices for torque wrenches, Edition 02/2020, Revision 0,
    Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin.
    DOI: 10.7795/550.20200825A, Opens external link in new windowDownload
    - Spanische Ausgabe Directriz DKD-R 10-8, Calibración estática de instalaciones de calibración para llaves dinamométricas, Edición 02/2020, Revisión 0,
    Physikalisch-Technische Bundesanstalt, Braunschweig y Berlín.
    DOI: 10.7795/550.20200825B, Opens external link in new windowDownload

  • DIN EN ISO 6789-2:2017-07 - Handbetätigte Drehmoment-Werkzeuge – Teil 2: Anforderungen an die Kalibrierung und Bestimmung der Messunsicherheit (ISO 6789-2:2017), Deutsche Fassung EN ISO 6789-2:2017, Beuth Verlag, Berlin
    - Englische Ausgabe ISO 6789-2:2017, Assembly tools for screws and nuts – Hand torque tools – Part 2: Requirements for calibration and determination of measurement uncertainty, ISO, 2017

  • BS 7882:2017 - Method for Calibration and Classification of Torque Measuring Devices, BSI, 2017,
    DOI: 10.3403/30340201

  • ASTM E2428-08 - Standard Practice of Calibration of Torque Measuring Instruments for Verifying the Torque Indication of Torque Testing Machines, ASTM, 2015,
    DOI: 10.1520/E2428-08

  • EURAMET/cg-14/Version 2.0 - Guidelines on the Calibration of Static Torque Measuring Devices, Ausgabe 03/2011, (Previously EA-10/14), ISBN 978-3-942992-11-4,
    Opens external link in new windowDownload 