- Photon radiation
- Beta radiation
Photon radiation
Absorbed dose rate to water
1) Contact person: Dr. H.-J. Selbach, Phone: +49 531 592 6220, Fax: +49 531 592 6205
2) Contact person: Dr. R.-P. Kapsch, Phone: +49 531 592 6210, Fax: +49 531 592 6205
| Description |
Details |
| X-radiation, 10 kV - 420 kV (DIN 6809/4 1988; DIN 6809/5, 1996)(1) |
|
| γ-radiation, 60Co (DIN 6800/2, 2008)(2) |
|

Reference air kerma rate
Contact person: Dr. H.-J. Selbach, Phone: +49 531 592 6220, Fax: +49 531 592 6405
| Description |
Details |
| γ-radiation, 192Ir |
|
| γ-radiation, 60Co |
|
| X-radiation and γ-radiation, 125I |
|

Ambient dose equivalent rate in 10 mm depth
1) Contact person: Dr. O. Hupe, Phone: +49 531 592 6310, Fax: +49 531 592 6015
Order form for calibrations/tests; Orderform for irradiation (to fill in)
2) Contact person: Dr. S. Neumaier, Phone: +49 531 592 6320, Fax: +49 531 592 6015
| Description |
Details |
| X-radiation (ISO 4037) |
|
| Gamma radiation (ISO 4037)1) |
|
| Gamma radiation (Calibration at low dose rates)2) |
| High-energy photon radiation |
|

Directional dose equivalent rate in 0.07 mm depth
Contact person: Dr. O. Hupe, Phone: +49 531 592 6310, Fax: +49 531 592 6015
Order form for calibrations/tests; Orderform for irradiation (to fill in)
| Description |
Details |
| X-radiation (ISO 4037) |
|
| Gamma radiation (ISO 4037) |
|

Personal dose equivalent in 10 mm depth
Contact person: Dr. O. Hupe, Phone: +49 531 592 6310, Fax: +49 531 592 6015
Order form for calibrations/tests; Orderform for irradiation (to fill in)
| Description |
Details |
| X-radiation (ISO 4037) |
|
| Gamma radiation (ISO 4037) |
|
| High-energy photon radiation (ISO 4037) |
|

Personal dose equivalent in 0.07 mm depth
Contact person: Dr. O. Hupe, Phone: +49 531 592 6310, Fax: +49 531 592 6015
Order form for calibrations/tests; Orderform for irradiation (to fill in)
| Description |
Details |
| X-radiation (ISO 4037) |
|
| Gamma radiation (ISO 4037) |
|

Air kerma rate
1) Contact person: Dr. L. Büermann, Phone: +49 531 592 6250, Fax: +49 531 592 6205
2) Contact person: Dr. S. Neumaier, Phone: +49 531 592 6320, Fax: +49 531 592 6015
| Description |
Details |
| X-rays, diagnostic (IEC 61267) |
|
| X-rays, radiation protection (ISO 4037) |
| Gamma radiation (ISO 4037)1) |
|
| Gamma radiation (Calibration at low dose rates)2) |
Contact person: Dr. O. Hupe, Phone: +49 531 592 6310, Fax: +49 531 592 6015
| High-energy photon radiation |
|

Contact person: Dr. L. Büermann, Phone: +49 531 592 6250, Fax: +49 531 592 6205
| Description |
Details |
| X-rays, diagnostic (IEC 61267) |
|

Air kerma-area product
Contact person: Dr. L. Büermann, Phone: +49 531 592 6250, Fax: +49 531 592 6205
| Description |
Details |
| X-rays, diagnostic (IEC 61267) |
|

X-ray tube voltage
Contact person: Dr. L. Büermann, Phone: +49 531 592 6250, Fax: +49 531 592 6205
| Description |
Details |
| X-rays, diagnostic (IEC 61267) |
|

Beta radiation
Directional dose equivalent rate in 0.07 mm depth
Contact person: R. Behrens, Phone: +49 531 592 6340, Fax: +49 531 592 69 6340
Orderform for irradiation (to fill in)
| Description |
Details |
| Pm, Tl, Kr, Sr/Y, Ru/Rh (ISO 6980) |
|

Personal dose equivalent in 0.07 mm depth
Contact person: R. Behrens, Phone: +49 531 592 6340, Fax: +49 531 592 69 6340
Orderform for irradiation (to fill in)
| Description |
Details |
| Pm, Tl, Kr, Sr/Y, Ru/Rh (ISO 6980) |
|

Absorbed dose rate to ICRU soft tissue
Contact person: R. Behrens, Phone: +49 531 592 6340, Fax: +49 531 592 69 6340
Orderform for irradiation (to fill in)
| Description |
Details |
| C, Pm, Tl, Kr, Sr/Y, Ru/Rh (ISO 6980) |
|

Absorbed dose rate to water
Contact person: Dr. H.-J. Selbach, Phone: +49 531 592 6220, Fax: +49 531 592 6205
| Description |
Details |
| Sr-90/Y-90 |
|

|
© Physikalisch-Technische Bundesanstalt Page created: 2004-03-18, last update: 2012-05-09, Webmaster Abt. 6 |
|
|