zum Seiteninhalt

Physikalisch-Technische Bundesanstalt

FachabteilungenAbt. 4 Optik 4.5 Optische Technologien4.54 Laserradiometrie > Publikationen
Laserradiometrie
Arbeitsgruppe 4.54

Ausgewählte Publikationen

  • W. Schmunk, M. Gramegna, G. Brida, I. P. Degiovanni, M. Genovese, H. Hofer, S. Kück, L. Lolli, M. G. A. Paris, S. Peters, M. Rajteri, A.M. Racu, A. Ruschhaupt, E. Taralli, P. Traina: „Photon number statistics of NV-centre emission”, accepted for publication in Metrologia

  • W. Schmunk, M. Rodenberger, S. Peters, H. Hofer, S. Kück: „Radiometric Calibration of Single Photon Detectors by a Single Photon Source based on NV-centers in diamond“, Journal of Modern Optics 58, 1252 (2011)

  • K. Amemiya, S. Mukai, Y. Ichino, T. Zama, S. Kück, B. Hartree, A. Deadman: "Final report on APMP.PR-S4: Comparison of fiber optic power meter responsivity”, Metrologia 48, 02004 (2011), doi: 10.1088/0026-1394/48/1A/02004

  • S. Kück, F. Brandt, M. L. Dowell, C. L. Cromer, D. A. Keenan: "Bilateral comparison of power measurement standards for KrF excimer lasers between PTB and NIST”, MAPAN – Journal Metrology Society of India 25, 37 (2010)

  • F. Brandt, S. Kück, A. Grütz: "Traceable laser power measurements of diode laser radiation in the near infrared", MAPAN – Journal Metrology Society of India 25, 29 (2010)

  • M. López, J. C. Molina, H. Hofer, A. Sperling, S. Kück: "Measurement of the nonlinearity of Ge- and InGaAs-photodiodes at high irradiance levels", MAPAN – Journal Metrology Society of India 25, 47 (2010)

  • S. Kück: "Final report on EUROMET comparison EUROMET.PR-S2 (Project No. 156): Responsivity of detectors for radiant power of lasers", Metrologia 47, 02003 (2010)

  • M. López, H. Hofer, K. D. Stock, J. Bermúdez, A. Schirmacher, F. Schneck, S. Kück: "Spectral reflectance and responsivity of Ge- and InGaAs-photodiodes in the near-infrared: measurement and model", Applied Optics 46, 7337 (2007)

  • M. López, H. Hofer, S. Kück: "High accuracy measurement of the absolute spectral responsivity of Ge and InGaAs trap detectors by direct calibration against an electrically calibrated cryogenic radiometer in the near-infrared", Metrologia 43, 508–514 (2006)

  • S. Kück, F. Brandt, H.-A. Kremling, A. Gottwald, A. Hoehl, M. Richter: "Absolute measurement of F2-laser power at 157 nm", Applied Optics 45, 3325–3330 (2006)

  • M. López, H. Hofer, S. Kück: "Measurement of the absorptance of a cryogenic radiometer cavity in the visible and near infrared", Metrologia 42, 400–405 (2005)

  • S. Kück, F. Brandt, M. Taddeo: "Gold-coated copper cone detector as new standard detector for F2 laser radiation at 157 nm", Applied Optics 44, 2258–2265 (2005)

  • S. Kück, K. Liegmann, K. Möstl, F. Brandt, J. Metzdorf: “Laser radiometry for UV-lasers at 193 nm”, in Laser-Induced Damage in Optical Materials: 2002 and 7th International Workshop on Laser Beam and Optics Characterization, edited by Gregory J. Exarhos, Arthur H. Guenther, Norbert Kaiser, Keith L. Lewis, M. J. Soileau, Christopher J. Stolz, Adolf Giesen, Horst Weber, (SPIE, Bellingham, WA, 2003), pp. 645-655

  • K. Stock, S. Kück, F. Brandt: Laserradiometrie, PTB-Mitteilungen 113, 361 (2003)

  • I. Vayshenker, H. Haars, X. Li, J. H. Lehman, D. J. Livigni: Optical-Fiber Power Meter Comparison between NIST and PTB. J. Res. Natl. Inst. Stand. Technol. 108, 391-394 (2003)

  • I. Vayshenker, H. Haars, X. Li, J. H. Lehman, D. J. Livigni: Comparison of optical-power meters between the NIST and the PTB. Metrologia 37, 349-350 (2000)

  • X. Li, T. Scott, C. Cromer, D. Keenan; F. Brandt, K. Möstl, "PTB Power measurement standards for high-power lasers: comparison between the NIST and the PTB", Metrologia 37 (2000) 445-447

  • F. Brandt, K. Möstl: "Kalibrierung von Leistungsmeßgeräten für Hochleistungslaser". In: Laser in Forschung und Technik, S. 730-733, Hrsg.: W. Waidelich, Springer-Verlag Berlin, etc. (1996). ISBN 3-540-61316-1

© Physikalisch-Technische Bundesanstalt, letzte Änderung: 2011-12-15, Webmaster Abteilung 4 Seite drucken DruckansichtPDF-Export PDF