On the basis of the laws of physics, standard devices used for the realisation of the pressure scale allow pressure values to be determined from:
Standard devices for the realisation of the pressure scale are validated within the scope of international comparisons between national metrology institutes (info).
Standard device | Measuring range | Pressure mode | |||
Designation | from | to | pabs | pe | Δp |
|
| 180 kPa | + | + | + | |
|
| 4 kPa |
| + | + | |
|
| 7 kPa | + | + |
| |
| 5 kPa | 7 MPa | + | + |
| |
| Twin pressure balance for differential pressure measurement in gases |
| 80 MPa |
|
| + |
| Liquid column for differential pressure measurement in gases; manometric liquid: Water |
| 10 kPa |
|
| + |
| Pressure balance; oil operated | 0,2 MPa | 1 GPa |
| + |
|
| Manganin-Manometer |
| 1,4 GPa |
| + |
|
The international admitted measurements are published in the database of International Bureau of Weights and Measures (BIPM).